TFIX-8M Facade fixing with metal nail
Versatile hammer-in facade fixing with steel nail recommended for ETICS.
Features and benefits
- Simple installation in all standard substrates (A,B,C).
- Excellent plate stiffness (value 1.0 kN/mm) ensures smooth elevation surface and stable insulation system.
- The long plastic overmoulding on the TFIX-8M nail minimises thermal bridging (value 0.002W/K), contributing to energy-saving benefits.
- Unique nail design allows for high load-bearing capacities. This reduces the quantity of fixings required per square metre of insulation.
- The shortest embedment depth at the maximum strength parameters
- Pre-assembled expansion nail saves time and labour.
- Can be used with additional KWL insulation holding plate, available in 90, 110 and 140mm flange sizes (recommended for soft insulation materials such as mineral wool).
Product information
Size |
Product Code |
Fixing |
Fixture |
||
Diameter |
Length |
Plate diameter |
Recommended thickness |
||
d |
L |
D |
tfix A, B, C |
||
[mm] | |||||
Ø8 |
TFIX-8M-095 |
8 |
95 |
60 |
60 |
TFIX-8M-115 |
8 |
115 |
60 |
80 |
Base material
-
Concrete C12/15-C50/60 (Use category A)
-
Solid Brick (Use category B)
-
Solid Sand-lime Brick (Use category B)
-
Hollow Brick (Use category C)
-
Vertically-perforated clay block (Use category C)
-
Hollow Sand-lime Brick (Use category C)
-
Lightweight Concrete Block (Use category C)
Applications
- External Thermal Insulation Composite Systems (ETICS)
- Polystyrene (EPS) boards
- Mineral wool (MW) boards
- Light wood wool building boards
- Polyurethane (PU) boards
- Cork boards
Installation guide
- Drill a hole of required diameter and depth
- Drilling depth of min 35-45mm in approved materials
- Lightly tap the plastic sleeve through the insulation material into hole with a hammer, until fixing depth is reached and plastic sleeve flush with insulation material
- Embedment depth of min 25mm in approved materials
- Hammer the nail into the plastic sleeve until fixing is secure and flush with insulation material.
- In soft insulation panels the fixing should be combined with insulation retaining plates KWL-90, KWL-110, KWL-140.
Installation data
Substrate |
A, B, C |
||
Hole diameter in substrate |
d0 |
[mm] |
8 |
Min. hole depth in substrate |
h0 |
[mm] |
35 |
Min. installation depth |
hnom |
[mm] |
25 |
Min. substrate thickness |
hmin |
[mm] |
100 |
Min. spacing |
smin |
[mm] |
100 |
Min. edge distance |
cmin |
[mm] |
100 |
Fixing diameter |
d |
[mm] |
8 |
Downloads
- TFIX-8M Facade fixing with metal nail - Technical Data Sheet
- 0244 rawlplug eng.pdf
- ETAS-07_0336 TFIX-8M en.pdf
- UKTA_TFIX-8M_0836-22_6337_2022_EN.pdf
Need documents for other product? Visit our Technical Library.
go to libraryContact us to get information about product availability and its price