R-XPTII-A4 Stainless Steel Throughbolt

Stainless steel throughbolt for non-cracked concrete

Features and benefits

  • Stainless steel anchor for the highest corrosion resistance
  • High performance in non-cracked concrete confirmed by ETA Option 7
  • Highest quality ensures maximum load capability
  • Suitable for reduced embedment to avoid contact with reinforcement
  • Embedment depth markings help to ensure precise installation of the anchor
  • Simple through-installation (drilling and installation through fixed material)

Contact us to get information about product availability and its price

Fill in the form with your details and send request for a R-XPTII-A4 Stainless Steel Throughbolt

Your request will be sent to our sales department. Please note this is not a purchase order.

    Product information

    Size

    Product Code

    Approval type

    Anchor

    Fixture

    Diameter

    Length

    Max. thickness tfix for:

    Hole diameter

    d

    L

    hnom,red

    hnom,std

    df

    -

    [mm]

    [mm]

    [mm]

    [mm]

    [mm]

    M6

    R-XPTIIA4-06050/10

    AT-15-7370/16

    6

    50

    10

    -

    7

    R-XPTIIA4-06055/10

    AT-15-7370/16

    6

    55

    15

    -

    7

    R-XPTIIA4-06085/25

    AT-15-7370/16

    6

    85

    45

    25

    7

    R-XPTIIA4-06100/40

    AT-15-7370/16

    6

    100

    40

    -

    7

    M8

    R-XPTIIA4-08060/10

    ETA 17/0782

    8

    60

    10

    -

    9

    R-XPTIIA4-08065/15

    ETA 17/0782

    8

    65

    15

    -

    9

    R-XPTIIA4-08075/10

    ETA 17/0782

    8

    75

    25

    10

    9

    R-XPTIIA4-08085/20

    ETA 17/0782

    8

    85

    35

    20

    9

    R-XPTIIA4-08095/30

    ETA 17/0782

    8

    95

    45

    30

    9

    R-XPTIIA4-08105/40

    ETA 17/0782

    8

    105

    55

    40

    9

    R-XPTIIA4-08115/50

    ETA 17/0782

    8

    115

    65

    50

    9

    M10

    R-XPTIIA4-10065/5

    ETA 17/0782

    10

    65

    5

    -

    11

    R-XPTIIA4-10080/20

    ETA 17/0782

    10

    80

    20

    -

    11

    R-XPTIIA4-10095/15

    ETA 17/0782

    10

    95

    35

    15

    11

    R-XPTIIA4-10115/35

    ETA 17/0782

    10

    115

    55

    35

    11

    R-XPTIIA4-10130/50

    ETA 17/0782

    10

    130

    70

    50

    11

    R-XPTIIA4-10140/60

    ETA 17/0782

    10

    140

    80

    60

    11

    M12

    R-XPTIIA4-12080/5

    ETA 17/0782

    12

    80

    5

    -

    13

    R-XPTIIA4-12100/5

    ETA 17/0782

    12

    100

    25

    5

    13

    R-XPTIIA4-12115/20

    ETA 17/0782

    12

    115

    40

    20

    13

    R-XPTIIA4-12120/25

    ETA 17/0782

    12

    120

    45

    25

    13

    R-XPTIIA4-12125/30

    ETA 17/0782

    12

    125

    50

    30

    13

    R-XPTIIA4-12150/55

    ETA 17/0782

    12

    150

    75

    55

    13

    R-XPTIIA4-12180/85

    ETA 17/0782

    12

    180

    105

    85

    13

    R-XPTIIA412200105

    ETA 17/0782

    12

    200

    105

    125

    13

    M16

    R-XPTIIA4-16125/5

    ETA 17/0782

    16

    125

    25

    5

    18

    R-XPTIIA4-16140/20

    ETA 17/0782

    16

    140

    40

    20

    18

    R-XPTIIA4-16150/30

    ETA 17/0782

    16

    150

    50

    30

    18

    R-XPTIIA4-16180/60

    ETA 17/0782

    16

    180

    80

    60

    18

    R-XPTIIA416220/100

    ETA 17/0782

    16

    220

    120

    100

    18

    M20

    R-XPTIIA4-20125/5

    ITB-KOT-2021/1944

    20

    125

    5

    -

    22

    R-XPTIIA4-20160/20

    ITB-KOT-2021/1944

    20

    160

    40

    20

    22

    R-XPTIIA4-20200/60

    ITB-KOT-2021/1944

    20

    200

    80

    60

    22

    R-XPTIIA4-20300/16

    ITB-KOT-2021/1944

    20

    300

    180

    160

    22

    M24

    R-XPTIIA4-24260/10

    ITB-KOT-2021/1944

    24

    260

    115

    100

    26

    Base material

    • Non-cracked concrete C20/25-C50/60

      Non-cracked concrete C20/25-C50/60

    • Unreinforced concrete

      Unreinforced concrete

    • Reinforced concrete

      Reinforced concrete

    For use also with

    • Natural Stone (after site testing)

      Natural Stone (after site testing)

    Applications

    • Cladding restraint
    • Curtain wall
    • Balustrading
    • Barriers
    • Handrails
    • Racking
    • Structural steel
    • Bollards

    Installation guide

    Installation guide
    Installation guide
    Installation guide
    Installation guide
    Installation guide
    1. Drill a hole of required diameter and depth
    2. Clear the hole of drilling dust and debris (using blowpump or equivalent method)
    3. Lightly tap the throughbolt through the fixture into hole with a hammer, until fixing depth is reached
    4. Insert bolt through fixture and tighten to the recommended torque

    Installation data

    Size

    M6

    M8

    M10

    M12

    M16

    M20

    M24

    Thread diameter

    d

    [mm]

    6

    8

    10

    12

    16

    20

    24

    Hole diameter in substrate

    d0

    [mm]

    6

    8

    10

    12

    16

    20

    24

    Installation torque

    Tinst

    [Nm]

    5

    15

    30

    50

    100

    180

    320

    Wrench size

    Sw

    [mm]

    10

    13

    17

    19

    24

    30

    36

    External diameter of washer

    [mm]

    12

    16

    20

    24

    30

    37

    44

    STANDARD EMBEDMENT DEPTH

    Min. hole depth in substrate

    h0,s

    [mm]

    55

    65

    79

    90

    110

    140

    155

    Min. installation depth

    hnom,s

    [mm]

    50

    55

    69

    80

    100

    120

    135

    Min. substrate thickness

    hmin,s

    [mm]

    100

    100

    120

    140

    170

    210

    230

    Min. spacing (Non-cracked concrete)

    smin, s

    [mm]

    45

    65

    90

    110

    170

    170

    180

    Min. edge distance (Non-cracked concrete)

    cmin, s

    [mm]

    50

    50

    60

    85

    90

    160

    200

    REDUCED EMBEDMENT DEPTH

    Min. hole depth in substrate

    h0,r

    [mm]

    40

    50

    59

    70

    90

    120

    140

    Min. installation depth

    hnom,r

    [mm]

    30

    40

    49

    60

    80

    100

    120

    Min. substrate thickness

    hmin,r

    [mm]

    100

    100

    100

    100

    130

    210

    230

    Min. spacing (Non-cracked concrete)

    smin,r

    [mm]

    40

    65

    115

    150

    190

    160

    190

    Min. edge distance (Non-cracked concrete)

    cmin,r

    [mm]

    45

    50

    80

    100

    120

    125

    160

    Downloads

    Need documents for other product? Visit our Technical Library.

    go to library

    Associated products

    • RT-MAXA Drill bits Aggressor SDS max

      RT-MAXA Drill bits Aggressor SDS max

    • RT-SDSA Drill bits Aggressor SDS plus

      RT-SDSA Drill bits Aggressor SDS plus

    • RT-IS Long impact sockets 1/2

      RT-IS Long impact sockets 1/2"

    • RT-SDSR Drill bits Rebardrill SDS plus

      RT-SDSR Drill bits Rebardrill SDS plus

    • R-BLOWPUMP Blow Pump

      R-BLOWPUMP Blow Pump

    Go to top