R-SPL-BP SafetyPlus – Bolt Projecting

High performance mechanical anchor - bolt projecting version

Features and benefits

  • High performance in non-cracked concrete confirmed by ETA Option 7
  • Design of SafetyPlus allows for easy through fixing
  • Integral controlled collapse and anti-rotation feature ensures fixture is firmly secured
  • Unique zig-zag feature provides balanced expansion, ensuring secure setting and maximised load-bearing capacity
  • Case-hardened nut with optimum taper angle for enhanced expansion
  • Fire resistant

Contact us to get information about product availability and its price

Fill in the form with your details and send request for a R-SPL-BP SafetyPlus – Bolt Projecting

Your request will be sent to our sales department. Please note this is not a purchase order.

    Product information

    Size

    Product Code

    Anchor

    Fixture

    Thread size

    External diameter

    Length

    Max. thickness

    Hole diameter

    d

    dnom

    L

    tfix

    df

    [mm]

    [mm]

    [mm]

    [mm]

    [mm]

    M10

    R-SPL-BP-10110/20

    10

    15

    110

    20

    17

    M12

    R-SPL-BP-12135/25

    12

    18

    135

    25

    20

    R-SPL-BP-12160/50

    12

    18

    160

    50

    20

    M16

    R-SPL-BP-16160/25

    16

    24

    160

    25

    26

    R-SPL-BP-16185/50

    16

    24

    185

    50

    26

    M20

    R-SPL-BP-20190/30

    20

    28

    190

    30

    30

    Base material

    • Non-cracked concrete C20/25-C50/60

      Non-cracked concrete C20/25-C50/60

    • Unreinforced concrete

      Unreinforced concrete

    • Reinforced concrete

      Reinforced concrete

    For use also with

    • Natural Stone (after site testing)

      Natural Stone (after site testing)

    Applications

    • Structural steel
    • Masonry support
    • Cladding restraints
    • Road Signs
    • Heavy machinery
    • Racking systems
    • Industrial doors
    • Safety barriers

    Installation guide

    Installation guide
    Installation guide
    Installation guide
    Installation guide
    Installation guide
    1. Drill a hole of required diameter and depth
    2. Clear the hole of drilling dust and debris (using blowpump or equivalent method)
    3. Insert anchor through fixture into hole and tap until required installation depth is achieved
    4. Tighten to the recommended torque

    Installation data

    Size

    M10

    M12

    M16

    M20

    Thread diameter

    d

    [mm]

    10

    12

    16

    20

    Hole diameter in substrate

    d0

    [mm]

    15

    18

    24

    28

    Installation torque

    Tinst

    [Nm]

    50

    80

    180

    275

    Wrench size

    Sw

    [mm]

    17

    19

    24

    30

    Min. hole depth in substrate

    h0

    [mm]

    95

    105

    130

    160

    Min. installation depth

    hnom

    [mm]

    80

    90

    110

    130

    Min. substrate thickness

    hmin

    [mm]

    105

    120

    150

    188

    Min. spacing

    smin

    [mm]

    70

    80

    100

    125

    Min. edge distance

    cmin

    [mm]

    105

    120

    150

    186

    Downloads

    Need documents for other product? Visit our Technical Library.

    go to library

    Associated products

    • RT-MAXA Drill bits Aggressor SDS max

      RT-MAXA Drill bits Aggressor SDS max

    • RT-SDSA Drill bits Aggressor SDS plus

      RT-SDSA Drill bits Aggressor SDS plus

    • RT-IS Long impact sockets 1/2

      RT-IS Long impact sockets 1/2"

    • RT-SDSR Drill bits Rebardrill SDS plus

      RT-SDSR Drill bits Rebardrill SDS plus

    • R-BLOWPUMP Blow Pump

      R-BLOWPUMP Blow Pump

    Go to top