R-LX-P-ZP Zinc plated Pan-Head Concrete Screw Anchor, Part 6

Self-tapping concrete screwbolt

Features and benefits

  • Time-efficient through-fixing installation with streamlined procedure - simply drill and drive.
  • Completely removable with possibility of reuse
  • Unique design with patented threadform ensures high performance for relatively small hole diameter
  • Non-expansion functioning ensures low risk of damage to base material and makes R-LX ideal for installation near edges and adjacent anchors
  • High performance in both uncracked and cracked concrete
  • Different head types for any application
  • Oversize head for fixtures with elongated holes
  • Excellent product for temporary fixing
  • Suitable for standard and reduced embedment depth

Contact us to get information about product availability and its price

Fill in the form with your details and send request for a R-LX-P-ZP Zinc plated Pan-Head Concrete Screw Anchor, Part 6

Your request will be sent to our sales department. Please note this is not a purchase order.

    Product information

    Size

    Product Code

    Anchor

    Fixture

    Diameter

    Length

    Max. thickness tfix for:

    Hole diameter

    d

    L

    hnom,min

    hnom,red

    hnom,std

    df

    [mm]

    [mm]

    [mm]

    [mm]

    [mm]

    [mm]

    6

    R-LX-06X040-P-ZP

    7.5

    40

    5

    1

    -

    9

    Base material

    • Cracked concrete C20/25-C50/60

      Cracked concrete C20/25-C50/60

    • Non-cracked concrete C20/25-C50/60

      Non-cracked concrete C20/25-C50/60

    • Hollow-core Slab C30/37-C50/60

      Hollow-core Slab C30/37-C50/60

    • Reinforced concrete

      Reinforced concrete

    • Unreinforced concrete

      Unreinforced concrete

    For use also with

    • Concrete

      Concrete

    • Natural Stone (after site testing)

      Natural Stone (after site testing)

    Applications

    • Formwork support systems
    • Balustrading & handrails
    • Fencing & gates manufacturing and installation
    • Racking systems
    • Public seating
    • Scaffolding

    Installation guide

    Installation guide
    Installation guide
    Installation guide
    Installation guide
    1. Drill the hole with rotary hammer drilling machine. Drill to a required depth.
    2. Blow out dust at least 4 times with a hand pump.
    3. Tighten the anchor to the fixture.
    4. After installation a further turning of the screw must not be possible. The head of the screw must be in contact with the fixture and is not damaged.

    Installation data

    Normal concrete

    Size

    6

    Thread diameter

    d

    [mm]

    7.5

    Hole diameter in substrate

    d0

    [mm]

    6

    Screw drive

    -

    [-]

    T30

    Head diameter

    [mm]

    14.6

    Max. torque for impact screw driver

    Timp,max

    [Nm]

    400

    REDUCED EMBEDMENT DEPTH

    Min. hole depth in substrate

    h0,r

    [mm]

    50

    Real hole depth in substrate

    h0

    [mm]

    L + 10 - tfix

    Min. installation depth

    hnom,r

    [mm]

    39

    Min. substrate thickness

    hmin,r

    [mm]

    80

    Min. spacing

    smin,r

    [mm]

    45

    Min. edge distance

    cmin,r

    [mm]

    45

    MINIMUM EMBEDMENT DEPTH

    Min. hole depth in substrate

    h0,min

    [mm]

    45

    Real hole depth in substrate

    h0

    [mm]

    L + 10 - tfix

    Min. installation depth

    hnom,min

    [mm]

    35

    Min. substrate thickness

    hmin,min

    [mm]

    80

    Min. spacing

    smin,min

    [mm]

    45

    Min. edge distance

    cmin,min

    [mm]

    45

    Hollow concrete slab

    Size

    6

    Thread diameter

    d

    [mm]

    7.5

    Hole diameter in substrate

    d0

    [mm]

    6

    Screw drive

    -

    [-]

    T30

    Head diameter

    [mm]

    14.6

    Max. torque for impact screw driver

    Timp,max

    [Nm]

    400

    REDUCED EMBEDMENT DEPTH

    Min. hole depth in substrate

    h0,r

    [mm]

    50

    Real hole depth in substrate

    h0

    [mm]

    L + 10 - tfix

    Min. installation depth

    hnom,r

    [mm]

    39

    Min. substrate thickness

    hmin,r

    [mm]

    80

    Min. spacing

    smin,r

    [mm]

    45

    Min. edge distance

    cmin,r

    [mm]

    45

    MINIMUM EMBEDMENT DEPTH

    Min. hole depth in substrate

    h0,min

    [mm]

    45

    Real hole depth in substrate

    h0

    [mm]

    L + 10 - tfix

    Min. installation depth

    hnom,min

    [mm]

    35

    Min. substrate thickness

    hmin,min

    [mm]

    80

    Min. spacing

    smin,min

    [mm]

    45

    Min. edge distance

    cmin,min

    [mm]

    45

    Downloads

    Need documents for other product? Visit our Technical Library.

    go to library

    Associated products

    • RT-MAXA Drill bits Aggressor SDS max

      RT-MAXA Drill bits Aggressor SDS max

    • RT-SDSA Drill bits Aggressor SDS plus

      RT-SDSA Drill bits Aggressor SDS plus

    • RT-SDSR Drill bits Rebardrill SDS plus

      RT-SDSR Drill bits Rebardrill SDS plus

    • R-BLOWPUMP Blow Pump

      R-BLOWPUMP Blow Pump

    Go to top