R-LX-HF-ZP Zinc plated Hex with Flange Concrete Screw Anchor
Self-tapping concrete screwbolt
Technical Data Sheet
R-LX-HF-ZP Zinc plated Hex with Flange Concrete Screw Anchor - Technical Data SheetFeatures and benefits
- Time-efficient through-fixing installation with streamlined procedure - simply drill and drive.
- Completely removable with possibility of reuse
- Unique design with patented threadform ensures high performance for relatively small hole diameter
- Non-expansion functioning ensures low risk of damage to base material and makes R-LX ideal for installation near edges and adjacent anchors
- High performance in both uncracked and cracked concrete
- Different head types for any application
- Oversize head for fixtures with elongated holes
- Excellent product for temporary fixing
- Suitable for standard and reduced embedment depth
Product information
Size |
Product Code |
Approval type |
Anchor |
Fixture |
|||
Diameter |
Length |
Max. thickness tfix for: |
Hole diameter |
||||
d |
L |
hnom,red |
hnom,std |
df |
|||
- |
[mm] |
[mm] |
[mm] |
[mm] |
[mm] |
||
5 |
R-LX-05X050-HF-ZP |
ETA-17/0783 |
6.2 |
50 |
- |
7 |
7 |
R-LX-05X075-HF-ZP |
ETA-17/0783 |
6.2 |
75 |
- |
32 |
7 |
|
6 |
R-LX-06X035-HF-ZP |
ETA-17/0783 |
7.5 |
35 |
- |
- |
9 |
R-LX-06X040-HF-ZP |
ETA-17/0783 |
7.5 |
40 |
1 |
- |
9 |
|
R-LX-06X050-HF-ZP |
ETA-17/0783 |
7.5 |
50 |
7 |
- |
9 |
|
R-LX-06X060-HF-ZP |
ETA-17/0783 |
7.5 |
60 |
17 |
5 |
9 |
|
R-LX-06X075-HF-ZP |
ETA-17/0783 |
7.5 |
75 |
32 |
20 |
9 |
|
R-LX-06X090-HF-ZP |
ETA-17/0783 |
7.5 |
90 |
47 |
35 |
9 |
|
R-LX-06X100-HF-ZP |
ETA-17/0783 |
7.5 |
100 |
57 |
45 |
9 |
|
R-LX-06X130-HF-ZP |
ETA-17/0783 |
7.5 |
130 |
87 |
75 |
9 |
|
R-LX-06X150-HF-ZP |
ETA-17/0783 |
7.5 |
150 |
107 |
95 |
9 |
|
8 |
R-LX-08X060-HF-ZP |
ETA-17/0783 |
9.9 |
60 |
10 |
- |
12 |
R-LX-08X075-HF-ZP |
ETA-17/0783 |
9.9 |
75 |
25 |
5 |
12 |
|
R-LX-08X090-HF-ZP |
ETA-17/0783 |
9.9 |
90 |
40 |
20 |
12 |
|
R-LX-08X100-HF-ZP |
ETA-17/0783 |
9.9 |
100 |
50 |
30 |
12 |
|
R-LX-08X120-HF-ZP |
ETA-17/0783 |
9.9 |
120 |
70 |
50 |
12 |
|
R-LX-08X130-HF-ZP |
ETA-17/0783 |
9.9 |
130 |
80 |
60 |
12 |
|
R-LX-08X150-HF-ZP |
ETA-17/0783 |
9.9 |
150 |
100 |
80 |
12 |
|
10 |
R-LX-10X060-HF-ZP |
ETA-17/0783 |
12.4 |
60 |
5 |
- |
14 |
R-LX-10X065-HF-ZP |
ETA-17/0783 |
12.4 |
65 |
10 |
- |
14 |
|
R-LX-10X075-HF-ZP |
ETA-17/0783 |
12.4 |
75 |
20 |
- |
14 |
|
R-LX-10X085-HF-ZP |
ETA-17/0783 |
12.4 |
85 |
30 |
- |
14 |
|
R-LX-10X090-HF-ZP |
ETA-17/0783 |
12.4 |
90 |
35 |
5 |
14 |
|
R-LX-10X100-HF-ZP |
ETA-17/0783 |
12.4 |
100 |
45 |
15 |
14 |
|
R-LX-10X110-HF-ZP |
ETA-17/0783 |
12.4 |
110 |
55 |
25 |
14 |
|
R-LX-10X120-HF-ZP |
ETA-17/0783 |
12.4 |
120 |
65 |
35 |
14 |
|
R-LX-10X130-HF-ZP |
ETA-17/0783 |
12.4 |
130 |
75 |
45 |
14 |
|
R-LX-10X140-HF-ZP |
ETA-17/0783 |
12.4 |
140 |
85 |
55 |
14 |
|
R-LX-10X150-HF-ZP |
ETA-17/0783 |
12.4 |
150 |
95 |
65 |
14 |
|
14 |
R-LX-14X080-HF-ZP |
ETA-17/0783 |
17.4 |
80 |
5 |
- |
18 |
R-LX-14X105-HF-ZP |
ETA-17/0783 |
17.4 |
105 |
30 |
- |
18 |
|
R-LX-14X115-HF-ZP |
ETA-17/0783 |
17.4 |
115 |
40 |
- |
18 |
|
R-LX-14X135-HF-ZP |
ETA-17/0783 |
17.4 |
135 |
60 |
15 |
18 |
|
R-LX-14X160-HF-ZP |
ETA-17/0783 |
17.4 |
160 |
85 |
40 |
18 |
Base material
-
Cracked concrete C20/25-C50/60
-
Non-cracked concrete C20/25-C50/60
-
Reinforced concrete
-
Unreinforced concrete
For use also with
-
Concrete
-
Natural Stone (after site testing)
Applications
- Through-fixing
- Temporary anchorages
- Formwork support systems
- Balustrading & handrails
- Fencing & gates manufacturing and installation
- Racking systems
- Public seating
- Scaffolding
Installation guide
- Drill the hole with rotary hammer drilling machine. Drill to a required depth.
- Blow out dust at least 4 times with a hand pump.
- Possibility of unscrewing and re-screwing.
- Tighten to the recommended torque.
- After installation.
Installation data
Normal concrete
Size |
5 |
6 |
8 |
10 |
14 |
||
Hole diameter in substrate |
d0 |
[mm] |
5 |
6 |
8 |
10 |
14 |
Hole diameter in fixture |
df |
[mm] |
7 |
9 |
12 |
14 |
18 |
Wrench size |
Sw |
[mm] |
10 |
10 |
13 |
15 |
19 |
External diameter of washer |
[mm] |
13 |
14 |
18 |
22 |
32 |
|
Max. torque for impact screw driver |
Timp,max |
[Nm] |
200 |
400 |
900 |
950 |
950 |
MINIMUM EMBEDMENT DEPTH | |||||||
Min. hole depth in substrate |
h0,min |
[mm] |
- |
45 |
- |
- |
- |
Real hole depth in substrate |
h0 |
[mm] |
- |
L + 10 - tfix |
- |
- |
- |
Min. installation depth |
hnom,min |
[mm] |
- |
35 |
- |
- |
- |
Min. substrate thickness |
hmin,min |
[mm] |
- |
80 |
- |
- |
- |
Min. spacing |
smin,min |
[mm] |
- |
45 |
- |
- |
- |
Min. edge distance |
cmin,min |
[mm] |
- |
45 |
- |
- |
- |
REDUCED EMBEDMENT DEPTH | |||||||
Min. hole depth in substrate |
h0,r |
[mm] |
35 |
50 |
60 |
65 |
85 |
Real hole depth in substrate |
h0 |
[mm] |
L + 10 - tfix |
L + 10 - tfix |
L + 10 - tfix |
L + 10 |
L + 10 - tfix |
Min. installation depth |
hnom,r |
[mm] |
25 |
39 |
50 |
55 |
75 |
Min. substrate thickness |
hmin,r |
[mm] |
80 |
80 |
80 |
80 |
110 |
Min. spacing |
smin,r |
[mm] |
40 |
45 |
50 |
60 |
100 |
Min. edge distance |
cmin,r |
[mm] |
40 |
45 |
50 |
60 |
100 |
STANDARD EMBEDMENT DEPTH | |||||||
Min. hole depth in substrate |
h0,s |
[mm] |
50 |
65 |
80 |
95 |
130 |
Real hole depth in substrate |
h0 |
[mm] |
L + 10 - tfix |
L + 10 - tfix |
L + 10 - tfix |
L + 10 - tfix |
L + 10 - tfix |
Min. installation depth |
hnom,s |
[mm] |
40 |
55 |
70 |
85 |
120 |
Min. substrate thickness |
hmin,s |
[mm] |
80 |
84 |
110 |
130 |
190 |
Min. spacing |
smin, s |
[mm] |
40 |
45 |
50 |
60 |
100 |
Min. edge distance |
cmin, s |
[mm] |
40 |
45 |
50 |
60 |
100 |
Hollow concrete slab
Size |
5 |
6 |
8 |
10 |
14 |
||
Hole diameter in substrate |
d0 |
[mm] |
5 |
6 |
8 |
10 |
14 |
Hole diameter in fixture |
df |
[mm] |
7 |
9 |
12 |
14 |
18 |
Wrench size |
Sw |
[mm] |
10 |
10 |
13 |
15 |
19 |
External diameter of washer |
[mm] |
13 |
14 |
18 |
22 |
32 |
|
Max. torque for impact screw driver |
Timp,max |
[Nm] |
200 |
400 |
900 |
950 |
950 |
MINIMUM EMBEDMENT DEPTH | |||||||
Min. hole depth in substrate |
h0,min |
[mm] |
- |
45 |
- |
- |
- |
Real hole depth in substrate |
h0 |
[mm] |
- |
L + 10 - tfix |
- |
- |
- |
Min. installation depth |
hnom,min |
[mm] |
- |
35 |
- |
- |
- |
Min. substrate thickness |
hmin,min |
[mm] |
- |
80 |
- |
- |
- |
Min. spacing |
smin,min |
[mm] |
- |
45 |
- |
- |
- |
Min. edge distance |
cmin,min |
[mm] |
- |
45 |
- |
- |
- |
REDUCED EMBEDMENT DEPTH | |||||||
Min. hole depth in substrate |
h0,r |
[mm] |
35 |
50 |
60 |
65 |
85 |
Real hole depth in substrate |
h0 |
[mm] |
L + 10 - tfix |
L + 10 - tfix |
L + 10 - tfix |
L + 10 |
L + 10 - tfix |
Min. installation depth |
hnom,r |
[mm] |
25 |
39 |
50 |
55 |
75 |
Min. substrate thickness |
hmin,r |
[mm] |
80 |
80 |
80 |
80 |
110 |
Min. spacing |
smin,r |
[mm] |
40 |
45 |
50 |
60 |
100 |
Min. edge distance |
cmin,r |
[mm] |
40 |
45 |
50 |
60 |
100 |
STANDARD EMBEDMENT DEPTH | |||||||
Min. hole depth in substrate |
h0,s |
[mm] |
50 |
65 |
80 |
95 |
130 |
Real hole depth in substrate |
h0 |
[mm] |
L + 10 - tfix |
L + 10 - tfix |
L + 10 - tfix |
L + 10 - tfix |
L + 10 - tfix |
Min. installation depth |
hnom,s |
[mm] |
40 |
55 |
70 |
85 |
120 |
Min. substrate thickness |
hmin,s |
[mm] |
80 |
84 |
110 |
130 |
190 |
Min. spacing |
smin, s |
[mm] |
40 |
45 |
50 |
60 |
100 |
Min. edge distance |
cmin, s |
[mm] |
40 |
45 |
50 |
60 |
100 |
Downloads
- R-LX-HF-ZP Zinc plated Hex with Flange Concrete Screw Anchor - Technical Data Sheet
- EC Certificate - R-LX_2021_EN.pdf
- ETA_17-0783_2020_R-LX_EN.pdf
- UKTA_R-LX_Non-Struct_22_6346_2022_EN.pdf
Need documents for other product? Visit our Technical Library.
go to libraryContact us to get information about product availability and its price