R-HPTII-A4 "D" Stainless Steel Throughbolt with large washer
Stainless steel throughbolt anchor for cracked and non-cracked concrete
Technical Data Sheet
R-HPTII-A4 "D" Stainless Steel Throughbolt with large washer - Technical Data SheetFeatures and benefits
- Stainless steel anchor for the highest corrosion resistance
- High performance in cracked and non-cracked concrete confirmed by ETA Option 1
- Highest quality ensures maximum load capability
- For applications requiring fire resistance up to 120 minutes
- Suitable for reduced embedment to avoid contact with reinforcement
- Embedment depth markings help to ensure precise installation of the anchor
- Design of R-HPTII allows drilling and installing directly through the fixture and helps to reduce installation time
- Suitable for installation in corrosive environments category C1, C2, C3,C4 and C5
- Anchors can be used in earthquake risk zones - seismic category C1 and C2
Product information
Size |
Product Code |
Anchor |
Fixture |
|||
Diameter |
Length |
Max. thickness tfix for: |
Hole diameter |
|||
d |
L |
hnom,red |
hnom,std |
df |
||
[mm] |
[mm] |
[mm] |
[mm] |
[mm] |
||
M8 |
R-HPTIIA4D08060/10 |
8 |
60 |
10 |
- |
9 |
R-HPTIIA4D08075/10 |
8 |
75 |
25 |
10 |
9 |
|
R-HPTIIA4D08085/20 |
8 |
85 |
35 |
20 |
9 |
|
R-HPTIIA4D08095/30 |
8 |
95 |
45 |
30 |
9 |
|
R-HPTIIA4D08105/40 |
8 |
105 |
55 |
40 |
9 |
|
R-HPTIIA4D08115/50 |
8 |
115 |
65 |
50 |
9 |
|
M10 |
R-HPTIIA4D10065/5 |
10 |
65 |
5 |
- |
11 |
R-HPTIIA4D10080/20 |
10 |
80 |
20 |
- |
11 |
|
R-HPTIIA4D10095/15 |
10 |
95 |
35 |
15 |
11 |
|
R-HPTIIA4D10115/35 |
10 |
115 |
55 |
35 |
11 |
|
R-HPTIIA4D10130/50 |
10 |
130 |
70 |
50 |
11 |
|
R-HPTIIA4D10140/60 |
10 |
140 |
80 |
60 |
11 |
|
M12 |
R-HPTIIA4D12080/5 |
12 |
80 |
5 |
- |
13 |
R-HPTIIA4D12100/5 |
12 |
100 |
25 |
5 |
13 |
|
R-HPTIIA4D12115/20 |
12 |
115 |
40 |
20 |
13 |
|
R-HPTIIA4D12125/30 |
12 |
125 |
50 |
30 |
13 |
|
R-HPTIIA4D12150/55 |
12 |
150 |
75 |
55 |
13 |
|
R-HPTIIA4D12180/85 |
12 |
180 |
105 |
85 |
13 |
|
M16 |
R-HPTIIA4D16125/5 |
16 |
125 |
25 |
5 |
18 |
R-HPTIIA4D16140/20 |
16 |
140 |
40 |
20 |
18 |
|
R-HPTIIA4D16150/30 |
16 |
150 |
50 |
30 |
18 |
|
R-HPTIIA4D16180/60 |
16 |
180 |
80 |
60 |
18 |
Base material
-
Cracked concrete C20/25-C50/60
-
Non-cracked concrete C20/25-C50/60
-
Reinforced concrete
-
Unreinforced concrete
For use also with
-
Natural Stone (after site testing)
Applications
- Cladding restraints
- Barriers
- Structural steel
- Curtain walling
- Handrails
- Heavy Plant
- Balustrading
- Passenger lifts
- Facades
- Fencing & gates manufacturing and installation
- Masonry support
- Platforms
- Public seating
- Racking systems
Installation guide
- Drill a hole of required diameter and depth
- Clear the hole of drilling dust and debris (using blowpump or equivalent method)
- Lightly tap the throughbolt through the fixture into hole with a hammer, until fixing depth is reached
- Tighten to the recommended torque
Installation data
Size |
M8 |
M10 |
M12 |
M16 |
||
Thread diameter |
d |
[mm] |
8 |
10 |
12 |
16 |
Hole diameter in substrate |
d0 |
[mm] |
8 |
10 |
12 |
16 |
Installation torque |
Tinst |
[Nm] |
15 |
30 |
50 |
100 |
Wrench size |
Sw |
[mm] |
13 |
17 |
19 |
24 |
External diameter of washer |
[mm] |
24 |
30 |
37 |
50 |
|
STANDARD EMBEDMENT DEPTH | ||||||
Min. hole depth in substrate |
h0,s |
[mm] |
65 |
80 |
90 |
110 |
Min. installation depth |
hnom,s |
[mm] |
55 |
69 |
80 |
100 |
Min. substrate thickness |
hmin,s |
[mm] |
100 |
120 |
140 |
170 |
Min. spacing (Non-cracked concrete) |
smin, s |
[mm] |
55 |
70 |
90 |
135 |
Min. spacing (Cracked concrete) |
smin, s |
[mm] |
55 |
70 |
90 |
135 |
Min. edge distance (Non-cracked concrete) |
cmin, s |
[mm] |
40 |
50 |
55 |
80 |
Min. edge distance (Cracked concrete) |
cmin, s |
[mm] |
40 |
45 |
55 |
70 |
REDUCED EMBEDMENT DEPTH | ||||||
Min. hole depth in substrate |
h0,r |
[mm] |
50 |
60 |
70 |
90 |
Min. installation depth |
hnom,r |
[mm] |
40 |
49 |
60 |
80 |
Min. substrate thickness |
hmin,r |
[mm] |
100 |
100 |
100 |
130 |
Min. spacing (Non-cracked concrete) |
smin,r |
[mm] |
50 |
70 |
120 |
150 |
Min. spacing (Cracked concrete) |
smin,r |
[mm] |
50 |
70 |
120 |
150 |
Min. edge distance (Non-cracked concrete) |
cmin,r |
[mm] |
50 |
60 |
70 |
90 |
Min. edge distance (Cracked concrete) |
cmin,r |
[mm] |
40 |
50 |
70 |
85 |
Downloads
- R-HPTII-A4 "D" Stainless Steel Throughbolt with large washer - Technical Data Sheet
- 1488-CPR-0628-W_R-HPTIIA4_EN.pdf
- ETA_17-0185_2021_R-HPTII-A4_EN.pdf
- UKTA_R-HPTIIA4_0836-22_6203_2022_EN.pdf
Need documents for other product? Visit our Technical Library.
go to libraryContact us to get information about product availability and its price